{"id":21636,"date":"2019-08-26T13:52:35","date_gmt":"2019-08-26T13:52:35","guid":{"rendered":"https:\/\/www.simscale.com\/?page_id=21636"},"modified":"2026-02-20T13:31:32","modified_gmt":"2026-02-20T13:31:32","slug":"initial-conditions","status":"publish","type":"page","link":"https:\/\/www.simscale.com\/docs\/simulation-setup\/initial-conditions\/","title":{"rendered":"Initial Conditions"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">With initial conditions, users can define the initialization of various parameters in their system. The fields to initialize depend on the analysis type, physics, and also time dependency.<\/p>\n\n\n\n\n\n\n<p class=\"wp-block-paragraph\">To set the initial conditions of your simulation, simply navigate to the <em>Initial conditions<\/em> tab in the simulation tree. By expanding the tab, you will find a list of the fields to initialize.<\/p>\n\n\n<div class=\"wp-block-image is-resized\">\n<figure class=\"aligncenter size-full\"><a href=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/initial-conditions-simulation-tree.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"726\" height=\"692\" src=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/initial-conditions-simulation-tree.jpg\" alt=\"initial conditions in the simulation tree\" class=\"wp-image-44856\" srcset=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/initial-conditions-simulation-tree.jpg 726w, https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/initial-conditions-simulation-tree-300x286.jpg 300w\" sizes=\"auto, (max-width: 726px) 100vw, 726px\" \/><\/a><figcaption class=\"wp-element-caption\">Figure 1: <em>Initial condition<\/em> tab in the simulation tree, showing the parameters for steady-state incompressible analysis<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Before going through the lists of fields, let&#8217;s see how the initialization of the fields impacts steady-state and transient simulations.<\/p>\n\n\n\n<h2 id='time-dependency' id='time-dependency' class=\"wp-block-heading\" id=\"time-dependency\">Time-Dependency<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Initial conditions define the starting values for each solution field. Therefore, they play a vital role in the stability and computing time of steady-state simulations. To ensure a good convergence rate for a steady-state simulation, it&#8217;s a good practice to initialize the domain close to the expected solution.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In the case of transient analysis, the initial conditions are vital for the setup. They define the state of the system when time is equal to zero and will play a major role in the simulation. For instance, if we are studying the transient cooling effects of a piece of metal, there is a huge difference between initializing the metal part at 350 \\(K\\) or 800 \\(K\\).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The time dependency definition of a simulation is set under the <a href=\"https:\/\/www.simscale.com\/docs\/simulation-setup\/global-settings\/\"><em>Global settings<\/em><\/a>:<\/p>\n\n\n<div class=\"wp-block-image is-resized\">\n<figure class=\"aligncenter size-full\"><a href=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/simscale-time-dependency.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"404\" src=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/simscale-time-dependency.jpg\" alt=\"time dependency of a simulation in simscale steady-state transient\" class=\"wp-image-44854\" srcset=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/simscale-time-dependency.jpg 768w, https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/simscale-time-dependency-300x158.jpg 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><figcaption class=\"wp-element-caption\">Figure 2: In the <em>Global settings<\/em>, you can choose between steady-state and transient for the time-dependency of your simulation.<\/figcaption><\/figure>\n<\/div>\n\n\n<h2 id='methods-of-initialization' id='methods-of-initialization' class=\"wp-block-heading\" id=\"methods-of-initialization\">Methods of Initialization<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In SimScale, there are two main methods to initialize the domain: global and subdomain initialization.<\/p>\n\n\n\n<h3 id='global-initialization' id='global-initialization' class=\"wp-block-heading\" id=\"global-initialization\">Global Initialization<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">As the name suggests, the global initialization applies the initial condition to the entire domain.<\/p>\n\n\n<div class=\"wp-block-image is-resized\">\n<figure class=\"aligncenter size-full\"><a href=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/global-initialization-initial-conditions.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"405\" src=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/global-initialization-initial-conditions.jpg\" alt=\"global initialization initial conditions\" class=\"wp-image-44855\" srcset=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/global-initialization-initial-conditions.jpg 768w, https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/global-initialization-initial-conditions-300x158.jpg 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><figcaption class=\"wp-element-caption\">Figure 3: Global initialization of gauge pressure in an incompressible analysis<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Global initialization is the most commonly used type of initialization. However, for some simulations, we may choose to initialize a portion of the domain with a different value. In such cases, the subdomain initialization is very useful &#8211; find more details below.<\/p>\n\n\n\n<h3 id='subdomain-initialization' id='subdomain-initialization' class=\"wp-block-heading\" id=\"subdomain-initialization\">Subdomain Initialization<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The subdomain-based initialization allows users to initialize a field in a specific region of the domain called a <em>subdomain<\/em>. Note that the subdomain initialization overrides the global initialization:<\/p>\n\n\n<div class=\"wp-block-image is-resized\">\n<figure class=\"aligncenter size-full\"><a href=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/subdomain-initialization.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"769\" height=\"466\" src=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/subdomain-initialization.jpg\" alt=\"subdomain initialization simscale initial conditions\" class=\"wp-image-44857\" srcset=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/subdomain-initialization.jpg 769w, https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/subdomain-initialization-300x182.jpg 300w\" sizes=\"auto, (max-width: 769px) 100vw, 769px\" \/><\/a><figcaption class=\"wp-element-caption\">Figure 4: To add a new subdomain, expand the field and click on the <strong>&#8216;+ button&#8217;<\/strong>.<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">A subdomain can be defined using a <a href=\"https:\/\/www.simscale.com\/docs\/simulation-setup\/model\/geometry-primitives\/\"  rel=\" noopener\">geometry primitive<\/a> or by assigning a volume region. For a detailed guide on subdomain initialization, please refer to this <a href=\"https:\/\/www.simscale.com\/docs\/tutorials\/natural-convection-led-spotlight\/#initial-conditions\">tutorial<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Below, we will go through all parameters that can be initialized in SimScale. Please note that the list varies based on the analysis type and physics of your simulation.<\/p>\n\n\n\n<h2 id='initial-conditions-types' id='initial-conditions-types' class=\"wp-block-heading\" id=\"initial-conditions-types\">Initial Conditions Types<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Depending on the analysis type and physics, SimScale will require the initialization of different fields. Find below the fields available.<\/p>\n\n\n\n<h3 id='fluid-dynamics' id='fluid-dynamics' class=\"wp-block-heading\" id=\"fluid-dynamics\">Fluid Dynamics<\/h3>\n\n\n\n<h4 id='pressure' id='pressure' class=\"wp-block-heading\" id=\"pressure\">Pressure<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Note that the input pressure may be different, depending on the analysis type. For example, an <a href=\"https:\/\/www.simscale.com\/docs\/analysis-types\/incompressible-fluid-flow-analysis\/\"><em>incompressible<\/em><\/a> analysis requires gauge pressure, whereas a <a href=\"https:\/\/www.simscale.com\/docs\/analysis-types\/conjugate-heat-transfer-analysis\/\"><em>conjugate heat transfer<\/em><\/a> simulation with compressibility enabled requires the absolute modified pressure. The pressure field may be initialized with global and subdomain definitions.<\/p>\n\n\n\n<h4 id='velocity' id='velocity' class=\"wp-block-heading\" id=\"velocity\">Velocity<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">For velocity, you can define both global and subdomain initialization.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Note that there is a third type of velocity initialization available for some analysis types, named <a href=\"https:\/\/www.simscale.com\/docs\/simulation-setup\/simulation-control-fluid\/#potential-flow-initialization\"><em>potential flow initialization<\/em><\/a>. This setting initializes the velocity field with a potential flow, which can enhance the stability of velocity-driven flows.<\/p>\n\n\n<div class=\"wp-block-image is-resized\">\n<figure class=\"aligncenter size-full\"><a href=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/potential-flow-initialization.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"769\" height=\"483\" src=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/potential-flow-initialization.jpg\" alt=\"potential flow initialization simscale simulation control\" class=\"wp-image-44858\" srcset=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/potential-flow-initialization.jpg 769w, https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/potential-flow-initialization-300x188.jpg 300w\" sizes=\"auto, (max-width: 769px) 100vw, 769px\" \/><\/a><figcaption class=\"wp-element-caption\">Figure 5: The <em>Potential flow initialization<\/em> on\/off toggle is in the <em>Simulation control<\/em> settings.<\/figcaption><\/figure>\n<\/div>\n\n\n<h4 id='turbulence-parameters' id='turbulence-parameters' class=\"wp-block-heading\" id=\"turbulence-parameters\">Turbulence Parameters<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Turbulent kinetic energy (\\(k\\)), Specific dissipation rate (\\(\\omega\\)), and Dissipation rate (\\(\\epsilon\\)) are related to the level of turbulence in the domain. As the name suggests, these parameters are only available for initialization if you are using the <em>k-epsilon<\/em>, <em>k-omega<\/em>, or <em>k-omega SST<\/em> turbulence models in the <a href=\"https:\/\/www.simscale.com\/docs\/simulation-setup\/global-settings\/#turbulence-model\">global settings<\/a>. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In terms of initialization, \\(k\\) and \\(\\omega\\) are required for the <em>k-omega<\/em> and <em>k-omega SST<\/em> turbulence models, whereas \\(k\\) and \\(\\epsilon\\) are required for the <em>k-epsilon<\/em> model. For a good rule of thumb of the global initialization of the turbulence parameters, please refer to this <a href=\"https:\/\/www.simscale.com\/forum\/t\/defining-turbulent-boundary-conditions\/80895\">post<\/a>.<\/p>\n\n\n\n<h4 id='modified-turbulent-viscosity' id='modified-turbulent-viscosity' class=\"wp-block-heading\" id=\"modified-turbulent-viscosity\">Modified Turbulent Viscosity<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The parameter \\(\\widetilde{\\nu}\\), also known as modified turbulent viscosity, is exclusive to the LES Spalart Allmaras turbulence model. Find on <a href=\"https:\/\/www.simscale.com\/forum\/t\/defining-turbulent-boundary-conditions\/80895\">this page<\/a> a rule of thumb for its initialization.<\/p>\n\n\n\n<h4 id='passive-scalar-1' id='passive-scalar-1' class=\"wp-block-heading\" id=\"passive-scalar-1\">Passive Scalar 1<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The passive scalar initialization is related to the <a href=\"https:\/\/www.simscale.com\/docs\/simulation-setup\/advanced-concepts\/passive-scalar-sources\/\">passive scalar transport model<\/a>, which is available for <a href=\"https:\/\/www.simscale.com\/docs\/analysis-types\/incompressible-fluid-flow-analysis\/\"><em>incompressible<\/em><\/a> and <a href=\"https:\/\/www.simscale.com\/docs\/analysis-types\/convective-heat-transfer-analysis\/\"><em>convective heat transfer<\/em><\/a> analyses. Both subdomain and global initializations are available.<\/p>\n\n\n\n<h4 id='temperature' id='temperature' class=\"wp-block-heading\" id=\"temperature\">Temperature<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Some analysis types, such as <em><a href=\"https:\/\/www.simscale.com\/docs\/analysis-types\/convective-heat-transfer-analysis\/\">convective heat transfer<\/a> <\/em>and<em> <a href=\"https:\/\/www.simscale.com\/docs\/analysis-types\/conjugate-heat-transfer-analysis\/\">conjugate heat transfer<\/a><\/em> require temperature initialization, which can be done both globally, and via subdomains. For steady-state simulations, the best practice is to initialize the domain close to the expected solution.<\/p>\n\n\n\n<h4 id='turbulent-thermal-diffusivity' id='turbulent-thermal-diffusivity' class=\"wp-block-heading\" id=\"turbulent-thermal-diffusivity\">Turbulent Thermal Diffusivity<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The turbulent thermal diffusivity \\(\\alpha_t\\) is a parameter that is automatically calculated based on the turbulence parameters, density, and thermal properties of the material.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It is available for global initialization in analysis types that involve temperature.<\/p>\n\n\n\n<h4 id='eddy-viscosity' id='eddy-viscosity' class=\"wp-block-heading\" id=\"eddy-viscosity\">Eddy Viscosity<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">In CFD, the <em><a href=\"https:\/\/www.simscale.com\/docs\/simulation-setup\/boundary-conditions\/eddy-viscosity\/\">Eddy viscosity<\/a><\/em> has two main variants: turbulent dynamic viscosity (also known as \\(\\mu_t\\)) and turbulent kinematic viscosity (also known as \\(\\nu_t\\)). <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In SimScale, the eddy viscosity always refers to the turbulent dynamic viscosity, and can be calculated by Equation 1:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">$$Eddy\\ viscosity = \\frac{\\rho k}{\\omega} \\tag{1}$$<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Where \\(\\rho\\) is the density of the fluid. \\(k\\) and \\(\\omega\\) are the turbulent kinetic energy and specific dissipation rate, respectively.<\/p>\n\n\n\n<h4 id='phase-fraction' id='phase-fraction' class=\"wp-block-heading\" id=\"phase-fraction\">Phase Fraction<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The phase fraction initialization is exclusive to the <a href=\"https:\/\/www.simscale.com\/docs\/analysis-types\/multiphase-fluid-flow-analysis\/\"><em>multiphase<\/em><\/a> analysis type. With this setting, the user can define global or subdomain initialization for both phases being simulated.<\/p>\n\n\n\n<h3 id='solid-mechanics' id='solid-mechanics' class=\"wp-block-heading\" id=\"solid-mechanics\">Solid Mechanics<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Generally speaking, only nonlinear or transient solid mechanics analyses require initialization. Furthermore, it is worth noting that all initial conditions for solid mechanics accept subdomain initialization. Find below a list of the parameters available.<\/p>\n\n\n\n<h4 id='displacement' id='displacement' class=\"wp-block-heading\" id=\"displacement\">Displacement<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Displacement initialization is available for nonlinear <a href=\"https:\/\/www.simscale.com\/docs\/analysis-types\/static\"><em>static<\/em><\/a>, nonlinear <a href=\"https:\/\/www.simscale.com\/docs\/analysis-types\/thermomechanical\"><em>thermomechanical<\/em><\/a>, and <a href=\"https:\/\/www.simscale.com\/docs\/analysis-types\/dynamic\"><em>dynamic<\/em><\/a> analyses. It is worth mentioning that a <a href=\"https:\/\/www.simscale.com\/docs\/simulation-setup\/boundary-conditions\/tables\/\">table input<\/a> method is also available for global initialization.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The displacement initialization is useful for translating the initial position of certain parts for the simulation. In the example below, the initial CAD model for a snap-fit analysis has both parts connected. By applying a displacement initial condition to one of the parts, we can disconnect both parts without changing the CAD model:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/10\/snap-fit-initial-model-1.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1276\" height=\"587\" src=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/10\/snap-fit-initial-model-1.jpg\" alt=\"initial displacement for a dynamic snap fit analysis\" class=\"wp-image-47874\" srcset=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/10\/snap-fit-initial-model-1.jpg 1276w, https:\/\/frontend-assets.simscale.com\/media\/2021\/10\/snap-fit-initial-model-1-300x138.jpg 300w, https:\/\/frontend-assets.simscale.com\/media\/2021\/10\/snap-fit-initial-model-1-1024x471.jpg 1024w, https:\/\/frontend-assets.simscale.com\/media\/2021\/10\/snap-fit-initial-model-1-768x353.jpg 768w\" sizes=\"auto, (max-width: 1276px) 100vw, 1276px\" \/><\/a><figcaption class=\"wp-element-caption\">Figure 6: For this snap-fit analysis, we can either adjust the CAD model by translating one of the parts, or we can adjust the displacement initial condition.<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">As a result, the parts are separated in the initial state of the simulation:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/10\/snap-fit-results.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1122\" height=\"846\" src=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/10\/snap-fit-results.jpg\" alt=\"snap fit simulation results initial displacement\" class=\"wp-image-47875\" srcset=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/10\/snap-fit-results.jpg 1122w, https:\/\/frontend-assets.simscale.com\/media\/2021\/10\/snap-fit-results-300x226.jpg 300w, https:\/\/frontend-assets.simscale.com\/media\/2021\/10\/snap-fit-results-1024x772.jpg 1024w, https:\/\/frontend-assets.simscale.com\/media\/2021\/10\/snap-fit-results-768x579.jpg 768w\" sizes=\"auto, (max-width: 1122px) 100vw, 1122px\" \/><\/a><figcaption class=\"wp-element-caption\">Figure 7: Initial state of the snap-fit analysis. One of the parts was translated by 0.015 meters due to displacement initialization.<\/figcaption><\/figure>\n\n\n\n<h4 id='stress' id='stress' class=\"wp-block-heading\" id=\"stress\">Stress<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The definition of stress initialization requires all normal and shear components of stress, as in Figure 8:<\/p>\n\n\n<div class=\"wp-block-image is-resized\">\n<figure class=\"aligncenter size-full\"><a href=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/stress-initialization.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"394\" src=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/stress-initialization.jpg\" alt=\"stress initialization simscale\" class=\"wp-image-44866\" srcset=\"https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/stress-initialization.jpg 768w, https:\/\/frontend-assets.simscale.com\/media\/2021\/04\/stress-initialization-300x154.jpg 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><figcaption class=\"wp-element-caption\">Figure 8: Note that table input is available for both global and subdomain initialization of stress.<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">The normal components of stress are indicated with two of the same letters in the subscript (<em>xx<\/em>, <em>yy<\/em>, and <em>zz<\/em>) whereas the other entries represent shear stresses (<em>xy<\/em>, <em>xz<\/em>, and <em>yz<\/em>).<\/p>\n\n\n\n<h4 id='velocity' id='velocity' class=\"wp-block-heading\" id=\"velocity\">Velocity<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">For many <a href=\"https:\/\/www.simscale.com\/docs\/analysis-types\/dynamic\/\"><em>dynamic<\/em><\/a> simulations, such as drop tests, the initialization of velocity is very important.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As a reminder, dynamic analyses are inherently transient and consider inertia effects. Therefore, the initialization of the domain plays a major role in the solution.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For an example of a simulation that initializes velocity, please check out <a href=\"https:\/\/www.simscale.com\/docs\/tutorials\/crash-test-of-fsae-impact-attenuator\/\">this tutorial<\/a>.<\/p>\n\n\n\n<h4 id='acceleration' id='acceleration' class=\"wp-block-heading\" id=\"acceleration\">Acceleration<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Like velocity, this field is only available for <a href=\"https:\/\/www.simscale.com\/docs\/analysis-types\/dynamic\"><em>dynamic<\/em><\/a> and <a href=\"https:\/\/www.simscale.com\/docs\/analysis-types\/thermomechanical\"><em>thermomechanical<\/em><\/a> simulations (in <em>Dynamic<\/em> mode for the <em>Inertia effects<\/em>).<\/p>\n\n\n\n<h4 id='temperature' id='temperature' class=\"wp-block-heading\" id=\"temperature\">Temperature<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">The only two types of FEA analysis types that model temperature are <a href=\"https:\/\/www.simscale.com\/docs\/analysis-types\/thermomechanical\"><em>thermomechanical<\/em><\/a> and <a href=\"https:\/\/www.simscale.com\/docs\/analysis-types\/heat-transfer\"><em>heat transfer<\/em><\/a>. Please note that the initialization of temperature is only required for transient analysis.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>With initial conditions, users can define the initialization of various parameters in their system. The fields to...","protected":false},"author":5,"featured_media":44856,"parent":17179,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"templates\/template-documentation.php","meta":{"_acf_changed":false,"_crdt_document":"","inline_featured_image":false,"footnotes":""},"class_list":["post-21636","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.simscale.com\/wp-json\/wp\/v2\/pages\/21636","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.simscale.com\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.simscale.com\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.simscale.com\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.simscale.com\/wp-json\/wp\/v2\/comments?post=21636"}],"version-history":[{"count":0,"href":"https:\/\/www.simscale.com\/wp-json\/wp\/v2\/pages\/21636\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.simscale.com\/wp-json\/wp\/v2\/pages\/17179"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.simscale.com\/wp-json\/wp\/v2\/media\/44856"}],"wp:attachment":[{"href":"https:\/\/www.simscale.com\/wp-json\/wp\/v2\/media?parent=21636"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}